CIRCUIT BREAKERS: BOTTOM of BALCONY STAIRS (by David Lawyer, 1993) An "outlet" = convenience outlet = electrical outlet wire color: R=red Bk=black SANCTUARY CHANDELIERS: thru 1 1/4" cond., down 1. Balcony (#5) center bulb R 2. #2 & #4 center bulb R 3. #1 & #3 center bulb R 4a. Balcony (#5) outer bulbs Bk 4b. Rose window in balcony R 5. #2 & #4 outer bulbs Bk 10. #1 & #3 outer bulbs Bk (6 & 10 interchanged due to bad contact) OUTSIDE FLOODS on SANCTUARY STAINED GLASS WINDOWS: #1 nearest pulpit 7a. half of W. facade R Conduit 7: 1 1/4" down; 8&9: 3/4" down 7b. #1 S., #4 S. Bk 8a. #2 N., #4 N. & half of W. facade (overloaded) Bk 8b. #1 N., #3 N. Orange 9a. #3 S., #5 S. Bk 9b. #2 S., #5 N. Blue UPSTAIRS ROOMS above THROOP HALL (and partly 2nd floor Tower Room): 6a. N. Room (including foyer): lights, outlets: W. wall to S., S. wall to E. (Light socket over door to E. Fire Escape Room is on Exit circuit but light socket over W. closet door is on this circuit). Hallway light between N. room and Morrison room. Tower room: W. baseboard outlet & W closet light. 6b. Fire escape stairway room: all, (?? possible outlet in room behind drinking fountain) 11a. Morrison room (central large upstairs room): W. 1/3 (3 lights) & S. storage room. Outlet on N. wall. Lights in S. closet of sink room next to it. SW office W. outlet. (Light socket over a N. door is on Exit circuit.) 11b. Morrison room: E. 2/3, E. closet, Sink room (to tower room). Upstairs Janitors Closet (SE room at top of balcony stairs) ceiling light. ROOMS WEST of THROOP HALL (including upstairs) old Bk except 18b 12a. (Unknown, old wire goes up in center conduit of W triple conduits) 12b. Men's room: all, light in hallway just outside it & chair room opposite it. Janitors closet opposite here. Room N. of Balcony: lights & S. wall outlet only. Near N. sanctuary door: outlet & parking lot lights (on timer) 13a. This stairwell; Balcony: back wall sconces. 13b. Sanctuary Foyer (at E. end): lights and 2@ outlets in baseboard. Balcony: outlet under center of front row . 14a. Spare (not connected) 14b. Organ room: control circuits & light. 15a. Not connected 15b. Outlet at E end of S Sanctuary aisle below pew. 16a. Main entrance room & outside steps. (= Tower-Narthex); this hallway; 2nd fl. Tower Room: all except W. baseboard outlet and closet light (both on 10a). 16b. Upper tower room (up tower stairway), upstairs restroom & hall light outside it; upstairs skylighted room behind drinking fountain: light by door; archive room (skylighted room NE of top of central stairs): all including 6@ ceiling outlets. 17a. Choir: dressing room, lavatory, loft (light & outlet), seating on N. side of chancel (outlets and sconce --switch behind curtain); Organ console lights; 2 @ pulpit outlets (one low, hard-to-find, with an on-off switch and a red pilot lamp) 17b. Choir dressing room: outlet on S wall (used for sprinkler timers) 18a. All Pulpit front spotlights 18b. High ceiling lights above Chancel. Outlets on switch behind organ 19-20 FEED to STAGE CB SUBPANEL (2 @ 60 amp) Bk #6